Surveyor™ Tank & Line Pressure Monitoring

Advantages:

  • Compact units and excellent integration possibilities
  • Replaces need for a second P/V valve at lower cost
  • Redundancy & low power consumption
  • Absolute pressure senora, no venting, no leaks
  • No maintenance sensors and electronics
  • Cost effective installation
  • Long time stability
  • Easy to expand for monitoring of more points
  • Ready to integrate with Cargo/Ballast/
  • Service tank gauging
  • Type approved by all major classification societies

Pressure Sensor:

  • Accuracy (level): +/-0,1% of sensor range
  • Environment temp: -25 to 85ºC (-10 to 185ºF)
  • Media temperature: -25 - 130ºC (-10 - 280ºF)
  • Protection, in tank: IP 68
  • Protection, on deck: IP 66
  • Media: Sea water, hydrocarbons, chemicals, acids
  • Material: Inconel 625 or Titanium
  • Electrical interface: 4-20 mA
  • Electrical connection: 1 or 2 pair cable (0.5-1.25 mm²)
  • Intrinsic safe: Eex ia IIC T4
  • Overpressure: 18 bar
  • Burst pressure (<sec): 50 bar


Application for:

  • Chemical Tankers
  • Tankers for oil
  • Floating Storage Facilities


Functions:

  • Vapour Pressure Monitoring
  • Individual High and Low Alarms
  • System Malfunction Alarm
  • Alarm Outputs for external alarms


Control Unit TCU:

  • Dimensions: 240 x 125 x 50 (LxWxH)mm
  • Mounting on rail DIN 35
  • Power supply #1 (DC/DC): 24 VDC (18 to 31V)
  • Power supply #2 (insulated): 24VDC (22.5 to 27 V)
  • Power consumption: max. 90W
  • Power supply redundancy, automatic switchover
  • included (24 VDC) (battery back-up is optional)
  • Power supply and communication to I/O modules and TDU
  • Each TCU accomodates 16 x AN-ZB485
  • Communication to 3rd party: 1xRS485, 2xRS232
  • Dedicated outputs for flash lights and siren
  • Alarm relay output and silence input.
  • Visual and audible alarms in accordance with IMO “Code on Alarms and Indicators 1995”


Display Unit TDU :

  • Touch screen 5,7” colour TFT 400 cd/sqm
  • Dimensions: 200 x 150 x 45 (WxHxD)mm
  • Panel / console mounting
  • Cut-out: 150 x 130 (WxH)mm
  • Power supply from TCU
  • Communication with TCU: RS232
  • Colour: Blue NCS 3070R90B

 

 

 

 

Surveyor™ Temperature Monitoring

Pressure Sensor

  • Can handle digital and analog signal inputs
  • Sensors supported PT100, PT1000
  • (2 and 4 wire)


Advantages:

  • Compact Units
  • Easy to install
  • Low Power Consumption
  • Absolute Pressure Sensors, no venting, no leaks
  • No Maintenance
  • Cost Effective Installation
  • Long time Stability
  • Easy to Expand into Ballast/Service tank Gauging
  • Type Approved by all major classification societies


Application for:

  • Chemical Tankers
  • Tankers for oil
  • Floating Storage Facilities


Functions:

  • Temperature Monitoring
  • Individual Low / High Temperature Alarms
  • System Malfunction Alarm
  • Alarm Outputs for external alarms
  • Programmable outputs

Control Unit TCU:

  • Dimensions: 240 x 125 x 50 (LxWxH)mm
  • Mounting on rail DIN 35
  • Power supply #1 (DC/DC): 24 VDC (18 to 31V)
  • Power supply #2 (insulated): 24VDC (22.5 to 27 V)
  • Power consumption: max. 90W
  • Power supply redundancy, automatic switchover
  • included (24 VDC) (battery back-up is optional)
  • Power supply and communication to I/O modules and TDU
  • Each TCU accomodates 16 x AN-ZB485
  • Communication to 3rd party: 1xRS485, 2xRS232
  • Dedicated outputs for flash lights and siren
  • Alarm relay output and silence input.
  • Visual and audible alarms in accordance with IMO “Code on Alarms and Indicators 1995”

Display Unit TDU :

  • Touch screen 5,7” colour TFT 400 cd/sqm
  • Dimensions: 200 x 150 x 45 (WxHxD)mm
  • Panel / console mounting
  • Cut-out: 150 x 130 (WxH)mm
  • Power supply from TCU
  • Communication with TCU: RS232
  • Colour: Blue NCS 3070R90B

 



Fig. 1: Temperature sensor in a pocket, for installation from side. Typically used in stand-alone temperature monitoring system configuration. Sensor elements used are Pt1000 or Pt100.Another application of this sensor is for temperature monitoring in cargo tanks, when radar is used for ullage monitoring.Accuracy of temperature measurement is <0,5C




Fig. 2: Combined water ingress detection and temperature sensor. Only used as a part of our Water Ingress Detection System. This sensor has no application as a stand-alone temperature monitoring system configuration. Mesuring temperature is a secondary means of water detection in some dry bulk cargoes like grain, coal or chemicals, which exposed to excessive humidity tend to increase temeparture as a result of germinations or chemical reactions.Accuracy of temperature measurement is <0,5C

 


Fig. 3: Combined pressure and temperature sensor. Typically used in heated cargo tanks or HFO tanks with temperature of max 130C. sensor is in Inconel and offers extreme resistance to corrosion.This sensor is ueed for simultaneous measurement of weight/level of the liquid in tank and for temperature monitoring, which is also used for compensation of the readings of the hydrostatic pressure. Accuracy of temperature measurement is <0,5C

 

Download: 

TN250005 TCU-TDU-tank pressure.pdf (139kb)

TN550001 TCU-TDU-temperature-tank pressure.pdf (204kb)

 

 

Ariston hvitevarer
 Leter du etter informasjon om Ariston eller HotPoint hvitevarer?


Information in other languages
Ariston SURVEYOR™ Multipurpose Monitoring & Control System
Ariston Surveyor TM多功能监测控制系统
Surveyor TM系统的核心——多功能监测控制系统的介绍
Ariston SURVEYOR™ Multipurpose Monitoring & Control System
Ariston Surveyor TM多功能监测控制系统
Surveyor TM系统的核心——多功能监测控制系统的介绍



Information
Contact Info